HIGH-VOLTAGE TEMPERATURE
MEASURING ELEMENT IN BATTERIES

Type 4-CH-HV-KN-K

_____

Kapton Thermoelemente

General product features

Detail Design
Operating temperature -40 °C to +150 °C (3000 h)
Minimum bending radius 12 x wire diameter
Dielectric strength 3.7 kV AC and 6 kV DC
Inner sheath FEP
Outer sheath Polyurethane (PUR)
Version ISO Measurement tips insulated with HST*
Version N-ISO Measurement tips exposed 3 mm

*HST=heat shrink tube / Other versions can be delivered on request

Schematic illustration

Capton thermocouple
Schematische Darstellung

1 Lemo 8-pin connector
2 Cap
3 High-voltage cable 4-CH-HV-KN-K
4 HST black
5 HST red
6 HST yellow
7 HST blue
8 HST green
9 HST transparent
10 Outer sheath Ø 4.5 mm
11 Thermocouples type K 2 x 0.2 mm
12 Kapton wire 0.7 x 1.1 mm
13 FEP insulation thickness 0.4 mm
14 3 x coloured fibre
15 HV-TC marking

Umsetzung: Suthues Marketing / Staplerexperte.de